An online nitrate nitrogen sensor price is determined by more than the probe itself. Range configuration, signal output, cable length, mounting hardware, membrane-head service, calibration standards, controller scope, documentation and delivery all change the quoted project cost. YEXsensor YEX-S2-NON-S is a PVC-membrane ion-selective sensor offered in 0–100.00 mg/L or 0–1000.0 mg/L configurations, so a useful quotation begins with the real concentration profile.
Why Buyers Search for a online nitrate nitrogen sensor price
Buyers search for price when preparing a budget, comparing reagent-free ion-selective measurement with an analyzer, or replacing laboratory-only sampling with continuous trend data. Their main risk is accepting a low probe price without confirming the range, interference environment, maintenance consumables or integration scope. That can create a system that is inexpensive to purchase but expensive to validate and operate.
A disciplined selection process therefore begins with the decision the reading will support. Write down the process action, the acceptable uncertainty, the required response, the available maintenance resources and the reference method. This converts a broad product search into an engineering inquiry that a supplier can review.
How YEX-S2-NON-S Addresses the Engineering Problem
YEX-S2-NON-S provides 0.01 mg/L resolution on the 0–100.00 mg/L configuration and 0.1 mg/L on the 0–1000.0 mg/L configuration. Stated accuracy is ±10% of reading or ±2 mg/L, temperature accuracy is ±0.5°C, and the operating envelope is 0–40°C, pH 2.5–11 and pressure below 0.1 MPa. It supplies RS485 Modbus RTU, with optional 4–20 mA, and uses a replaceable membrane head.
The published values should be treated as configuration boundaries, not as permission to ignore the sample matrix. During technical clarification, ask the supplier to confirm the exact ordered version, supplied accessories, protocol document and any conditions that may affect the application. Put the confirmed information on the quotation or datasheet revision attached to the purchase order.
Technical Parameters for Selection and Procurement
| Selection item | Official specification | Procurement check |
|---|---|---|
| Principle | PVC-membrane nitrate ion-selective electrode | Confirm the measurand matches the project control objective |
| Range option 1 | 0–100.00 mg/L; 0.01 mg/L resolution | Submit minimum, normal, alarm and maximum process values |
| Range option 2 | 0–1000.0 mg/L; 0.1 mg/L resolution | Submit minimum, normal, alarm and maximum process values |
| Accuracy | ±10% of reading or ±2 mg/L; temperature ±0.5°C | Define acceptance points, reference method and allowable deviation |
| Temperature and pH | 0–40°C; pH 2.5–11 | Verify worst-case temperature, pH and pressure remain compliant |
| Pressure | <0.1 MPa | Confirm maximum line pressure, surges and isolation arrangement |
| Calibration | Two-point | Specify standards, verification method and maintenance access |
| Output | RS485 Modbus RTU; optional 4–20 mA | State PLC input, protocol settings and network topology |
| Supply | 12–24 VDC; 0.2 W | Size regulated power, protection and cable voltage drop |
| Mechanical | IP68; PVC/POM wetted material; 3/4 NPT | Check thread, immersion depth, materials and removal access |
| Installation and cable | Immersion or inline; 5 m standard cable, customizable | Confirm installed route length, shielding and junction requirements |
| Service feature | Replaceable membrane head | List replacement parts, storage conditions and planned stock |
What the Parameters Mean in a Real Project
The range option influences price and suitability. A 0–100 mg/L process should not be specified from a single average if peaks can exceed the upper limit.
Accuracy must be interpreted at the working concentration. The stated ±10% of reading or ±2 mg/L should be compared with the process decision and laboratory method.
Optional 4–20 mA can simplify a legacy control panel, while Modbus provides digital data and networking. The required output must be priced explicitly.
A replaceable membrane head makes lifecycle planning important: procurement should include expected service conditions, spares and a verification procedure.
How to Turn the Specification into a Purchase Decision
A technical table is only the beginning of selection. The project team should convert each value into a design condition, an acceptance check and an operating responsibility. Normal operation, start-up, cleaning, upset and seasonal conditions may be different. A sensor selected only from a normal average can be out of range during the event that matters most.
Separate the sensor specification from the complete measurement-point specification. The latter includes power, cable, junctions, mounting, isolation, controller or gateway, communication settings, calibration materials, access, cleaning, spare parts and documentation. This distinction makes quotations comparable and reduces change orders during commissioning.
Define the role of the measurement before selecting an alarm. A value used for operator awareness has different validation and redundancy needs from a signal that automatically changes chemical dosing or stops a process. For automatic action, define bad-signal behavior, communication timeout, high and low limits, rate-of-change limits and manual override. The control system should never interpret a disconnected or fouled sensor as a valid process demand.
Plan verification with the method the site actually trusts. Online and laboratory methods may measure different properties, sample different moments or respond differently to the matrix. Record sample location, time, temperature, cleaning state and process condition during comparisons. A useful acceptance plan defines expected agreement and investigation steps rather than promising that unlike methods will always return identical numbers.
online nitrate nitrogen sensor price: Application Fit and Limitations
A comparable quote should separate sensor, selected range, output option, cable, mounting, controller or gateway, calibration materials, spare membrane head, documentation, packing, freight and taxes where applicable. Buyers should also budget for reference analyses, planned cleaning and staff time. This prevents a probe-only price from being compared with a complete measurement point.
A suitable application stays inside the stated range and environmental limits, provides a representative sample, and gives operators access for maintenance. An unsuitable application asks the sensor to identify a parameter it does not measure, exposes it to unreviewed chemicals, or relies on a measurement point that cannot represent the process. Stating these limits in the purchase record protects both commissioning and future operation.
Typical Application Scenarios
Municipal wastewater process
Use continuous nitrate trend for biological process observation while retaining laboratory checks for validation and regulatory reporting as required.
Industrial wastewater
Provide ionic composition, pH, cleaning chemicals and expected interferents so suitability can be reviewed before price comparison.
Surface-water station
Include enclosure, power, communications, anti-fouling access and seasonal concentration range in the total station budget.
Pilot or research system
Define raw-data frequency, calibration records and reference sampling because data quality requirements can dominate the accessory scope.
In every scenario, trend quality depends on location and operating discipline. Document the installation elevation or depth, nearby dosing or return points, normal hydraulic condition and maintenance access. If the water is spatially variable, use more than one point or a documented sampling survey before assuming that a single sensor represents the complete system.
Installation and Integration Notes
Select a representative, mixed location within 0–40°C, pH 2.5–11 and pressure below 0.1 MPa. Provide safe access for removal and calibration. In streams with solids or biofilm, design a maintenance routine and avoid dead zones. Inline installation must preserve the pressure limit and allow isolation before removal.
For RS485 Modbus RTU integration, confirm supply voltage, polarity, A/B wiring convention, device address, baud rate, parity, stop bits and register map before energizing the loop. Use an appropriate bus topology, shielding and termination for the site. Store the protocol revision and final settings with the commissioning record so a replacement sensor or new gateway can be configured without reverse engineering.
Commissioning should include visual inspection, wiring checks, stable reading confirmation, calibration or verification, comparison with the reference method, alarm simulation and a communication-loss test. Train operators to distinguish a process excursion from fouling, air bubbles, an empty flow cell, damaged cable or expired calibration. These practical checks create more value than purchasing a sensor with no ownership plan.
How to Request a Comparable Quotation
Send one RFQ sheet that states the application, water source, minimum/normal/maximum value, temperature, pressure, pH where relevant, solids or fouling risk, installation method, thread or bracket, cable length, output, controller, power, quantity and destination. Add the required language, certificates, drawings, inspection records, packing and delivery terms. If a configuration is optional, request separate line-item pricing.
Ask the commercial offer to identify the model, exact range, output, wetted materials, included cable, accessories, protocol, warranty, lead time and exclusions. A clear line-item quotation lets procurement compare like with like and lets engineering confirm that the lowest initial price has not removed essential integration or maintenance scope.
Frequently Asked Questions About online nitrate nitrogen sensor price
What mainly determines online nitrate nitrogen sensor price?
The main drivers are range, RS485 versus optional 4–20 mA, cable length, mounting, controller scope, calibration materials, spare membrane head, quantity, documentation and shipping. A valid comparison uses the same scope and concentration range for every supplier.
Which range should I request?
Choose 0–100.00 mg/L with 0.01 mg/L resolution or 0–1000.0 mg/L with 0.1 mg/L resolution based on measured minimum, normal and peak concentrations. Include upset data so the selected range is not exceeded during important events.
Can the sensor replace laboratory nitrate testing?
It can provide continuous operational trend data, but replacement of a laboratory or compliance method depends on local rules, project validation and matrix performance. Procurement should include a correlation plan with paired samples rather than assuming automatic equivalence.
What accuracy should be used for acceptance?
The official specification is ±10% of reading or ±2 mg/L. The purchase specification should define the concentration points, standard or sample matrix, stabilization time and reference method used for acceptance.
Does it connect to an existing PLC?
Yes. Standard output is RS485 Modbus RTU, and 4–20 mA is optional. State PLC brand, available input, cable distance and whether multiple devices share the bus so the correct interface scope can be quoted.
What operating conditions must be disclosed?
Provide temperature within the stated 0–40°C range, pH within 2.5–11, pressure below 0.1 MPa, solids, ionic composition, cleaning chemicals and installation type. These conditions affect suitability and maintenance cost.
Why should a spare membrane head be considered?
The sensor uses a replaceable membrane head, so a planned spare can reduce downtime when service is required. Ask the quotation to list the supplied head, recommended spares and storage information separately.
Is 4–20 mA included automatically?
No. The product information lists RS485 Modbus RTU and optional 4–20 mA. If the site requires analog input, write it explicitly in the RFQ and confirm whether a converter, transmitter or configured output is included.
What information produces a firm quotation?
Send application, nitrate range, water analysis, temperature, pH, pressure, installation, output, cable length, quantity, accessories, required certificates and destination. Ask for line-item pricing and lead time so capital and lifecycle costs can be reviewed.
Summary
Selecting a online nitrate nitrogen sensor price requires a match between the actual process, the official product limits and the decision the reading will support. The YEX-S2-NON-S specifications provide a defined starting point, while installation, calibration, integration and lifecycle planning determine whether the project produces dependable data.
For a useful quotation, send the operating range, water conditions, mounting, cable, output, controller, quantity, documents and delivery destination. YEXsensor can then confirm the configured model and quote the complete measurement point instead of an ambiguous probe-only scope.