Online Chloride Ion Sensor Price: Industrial Water Procurement Guide

2026-08-06

An online chloride ion sensor price changes with the selected range, cable, installation, controller, calibration standards, spare strategy, documentation and delivery scope. YEXsensor YEX-S1-CLI-A uses a solid-state membrane ion-selective electrode and offers 0–3500 mg/L with 0.1 mg/L resolution or 0–35000 mg/L with 1 mg/L resolution, so the first commercial decision is the actual chloride concentration envelope.

YEX-S1-CLI-A online chloride ion sensor price

Why Buyers Search for a online chloride ion sensor price

Buyers search for price when monitoring desalination streams, industrial wastewater, brine leakage, cooling water or process-water contamination. They worry about selecting the lower range from normal data and then losing readings during a brine event, or paying for a high range that provides less useful resolution near a low alarm threshold.

The first selection task is therefore to write the decision the reading must support, the acceptable uncertainty, the required response, available maintenance resources and the reference method. This converts a broad product search into a reviewable engineering inquiry.

How the YEXsensor YEX-S1-CLI-A Solution Addresses the Project

YEX-S1-CLI-A has stated accuracy of ±5% with temperature accuracy of ±0.5°C, automatic Pt1000 compensation and two-point zero-and-slope calibration. It operates from 0–40°C, below 0.1 MPa and within pH 2–12. The POM, IP68 sensor uses 3/4 NPT submersible mounting, RS485 Modbus RTU, 12–24 VDC at 0.2 W and a standard 5 m customizable cable.

Published values are configuration boundaries, not permission to ignore the sample matrix. Ask YEXsensor to confirm the exact ordered version, supplied accessories, protocol revision and application limits on the quotation or attached datasheet.

YEX-S1-CLI-A measurement configuration

Technical Parameters for Selection and Procurement

Selection itemOfficial specificationProcurement check
PrincipleSolid-state membrane ion-selective electrodeConfirm principle matches the required measurand
Low range0–3500 mg/L; 0.1 mg/L resolutionCompare low range with minimum, normal and upset values
High range0–35000 mg/L; 1 mg/L resolutionCompare high range with minimum, normal and upset values
Accuracy±5%; temperature ±0.5°CDefine reference method and acceptance points for accuracy
Temperature0–40°CConfirm worst-case process limits for temperature
Pressure<0.1 MPaCheck operating, surge and isolation pressure for pressure
Applicable pH2–12Confirm installed length and termination for applicable ph
CompensationAutomatic Pt1000Record configuration and reference basis for compensation
CalibrationTwo-point, zero and slopeSpecify standards, access and records for calibration
OutputRS485 Modbus RTUState PLC interface and protocol details for output
Supply and consumption12–24 VDC; 0.2 W at 12 VSize power and protection for supply and consumption
Housing and protectionPOM; IP68Review chemical compatibility and ingress needs for housing and protection
Installation and cableSubmersible, 3/4 NPT; 5 m customizable cableConfirm installed length and termination for installation and cable

What the Parameters Mean in Engineering Practice

Range choice affects both suitability and price. Use actual minimum, normal, alarm and upset samples, including cleaning and brine-release events.

A ±5% specification should be translated into mg/L at the working point and compared with the process decision and reference-method uncertainty.

The pH 2–12 envelope is broad, but ion-selective response can still depend on sample composition and interfering ions. Provide a representative analysis during technical review.

A pressure limit below 0.1 MPa makes isolation and bypass design important for pressurized industrial lines. Do not assume direct insertion into any main.

YEX-S1-CLI-A technical and installation details

How to Turn Specifications into a Purchase Decision

A product table is not a complete measurement-point specification. Engineering should translate every value into a design condition, acceptance check and operating responsibility. Normal operation, start-up, cleaning, upset and seasonal conditions may differ. A sensor chosen only from an average can be out of range when the event that matters occurs.

Separate probe scope from system scope. A functioning point may need power, surge protection, cable, waterproof junctions, bracket or flow cell, controller, gateway, telemetry, calibration materials, spares and documents. Ask suppliers to identify inclusions and exclusions line by line so procurement compares equivalent systems.

Define how the value will be used. Operator trending, alarm generation, automatic dosing and regulatory reporting have different validation needs. Automatic control requires communication-timeout behavior, invalid-value handling, rate limits, interlocks and manual override. A disconnected, fouled or out-of-range sensor must not be interpreted as a valid demand.

Plan acceptance around the method the site trusts. Online and laboratory methods may measure different properties or sample different moments. Record location, time, temperature, maintenance condition and process state during comparisons. A practical acceptance plan defines expected agreement and investigation steps rather than promising identical numbers from unlike methods.

Before purchase, assign ownership for calibration, cleaning, alarm review, spare parts and data-quality records. Confirm who will investigate a failed comparison, who can change a setpoint and how long replacement or technical support may take. These responsibilities influence the practical value and lifecycle cost of the measurement as much as the probe specification.

online chloride ion sensor price: Application Fit and Limitations

A comparable quote should identify the exact 3500 or 35000 mg/L range, cable, mounting, calibration standards, controller or gateway, protocol document, spares, quantity, certificates, freight and commissioning support. Provide sample chloride, pH, temperature, pressure and major ions so technical suitability is reviewed before commercial comparison.

A suitable installation stays inside the stated range and environmental envelope, represents the process and remains accessible. An unsuitable installation asks the sensor to report a different analyte, exposes it to unreviewed chemistry or places it where flow, deposits or local dosing make the reading unrepresentative.

Typical Application Scenarios

Desalination process

Trend chloride breakthrough or stream changes with a range that covers both normal water and credible upset concentrations.

Cooling-water system

Use chloride trend with conductivity and corrosion-control data; chloride and conductivity are related but not interchangeable.

Industrial wastewater

Disclose high ionic strength, pH, temperature and interfering species before treating an ISE reading as a compliance result.

Brine leak detection

Choose alarm location and range from transport modeling and historical samples, then confirm alarms with an independent method.

In every application, document the monitoring location, nearby dosing or return points, normal hydraulic condition and service access. If the water is spatially variable, use multiple points or a documented survey before assuming one convenient location represents the complete system.

Installation and Integration Notes

Use a representative submerged point or a pressure-controlled bypass below 0.1 MPa. Avoid stagnant pockets, bubbles and direct chemical injection. Provide isolation and safe removal, keep cable junctions waterproof and configure Modbus settings before connection to the site network. Verify the selected range with standards and representative samples.

For digital integration, confirm power, polarity, A/B convention, address, baud rate, parity, stop bits and register map before energizing the loop. Use appropriate shielding, topology and termination. Store final settings with commissioning records so future replacement does not require reverse engineering.

Commissioning should include visual inspection, wiring checks, stable-reading confirmation, calibration or verification, reference comparison, alarm simulation and communication-loss testing. Train operators to distinguish a process excursion from fouling, bubbles, damaged cable, empty flow conditions or expired calibration.

YEX-S1-CLI-A field application

How to Request a Comparable Quotation

Send one RFQ sheet listing application, water source, measurand and units, minimum/normal/maximum values, temperature, pressure, pH and major ions where relevant, fouling, mounting, cable, output, controller, power, quantity and destination. Add required certificates, drawings, inspection records, packing and delivery terms.

Ask the offer to identify model, exact range, output, wetted materials, cable, accessories, protocol, warranty, lead time and exclusions. A line-item quotation helps engineering verify suitability and prevents a low probe price from hiding necessary integration or maintenance scope.

Frequently Asked Questions About online chloride ion sensor price

Which range has the lower detection detail?

The 0–3500 mg/L configuration has 0.1 mg/L resolution, while the 0–35000 mg/L configuration has 1 mg/L resolution. Select from real alarm and upset values, not from the widest available range.

Can it be installed directly in a pressurized pipeline?

The stated pressure limit is below 0.1 MPa. A controlled bypass with isolation may be required for higher-pressure lines. Send actual operating and surge pressure with the proposed mechanical arrangement.

Is chloride the same as conductivity or salinity?

No. Chloride is one ion, conductivity reflects the combined ability of dissolved ions to conduct electricity, and salinity is a broader dissolved-salt measure. Choose the parameter that matches the project decision.

What sample data helps obtain a firm price?

Provide minimum, normal and maximum chloride, pH, temperature, pressure, major ions, cleaning chemicals, mounting, cable, controller, quantity and destination. Ask for the configured range as a line item.

Does the online chloride ion sensor price solution connect to a PLC or SCADA system?

Yes. The stated interface is RS485 Modbus RTU. Confirm device address, baud rate, parity, register map, cable distance and network topology before ordering. Include the controller brand and required analog option, if any, in the RFQ.

Which operating conditions must be confirmed?

Confirm 0–40°C, pressure below 0.1 MPa, pH 2–12 and a representative ionic matrix compatible with the electrode. Also disclose solids, fouling, cleaners, interfering ions and upset conditions. A quotation should state the configured materials and limits rather than relying on a generic model name.

How should calibration be planned?

Use two-point zero-and-slope calibration with standards that bracket the selected range. Define standards, stabilization time, as-found and as-left records, paired samples and the person responsible. Calibration frequency should follow drift and fouling history rather than an unsupported universal interval.

Can the online sensor replace laboratory testing?

It provides continuous chloride-ion trend. Regulatory or contractual reporting still depends on the approved reference method and site validation. Use the online value for continuous trend and operational response, while retaining laboratory or reference checks required by regulation, contracts and the site quality plan.

What information should an RFQ contain?

Provide application, measurand, units, minimum/normal/maximum values, temperature, pressure, pH and matrix where relevant, installation, cable, output, controller, quantity, documents and destination. Request the exact configured model and included accessories.

YEX-S1-CLI-A procurement configuration

Summary

Selecting a online chloride ion sensor price requires a match between the real process, official product limits and the decision the data will support. The YEXsensor YEX-S1-CLI-A specifications provide a defined starting point, while installation, calibration, integration and lifecycle planning determine whether the project produces dependable information.

For a useful quotation, send operating range, matrix, mounting, cable, output, controller, quantity, required documents and destination. YEXsensor can then confirm the configured model and quote a complete measurement point instead of an ambiguous probe-only scope.

Send Inquiry
Tell us your requirements. Let's discuss more about your project.
Tell us your requirements so we can recommend the right sensor faster

A clear inquiry helps us confirm the suitable model, measuring range, installation method, output signal and datasheet without repeated emails.

  • Water type: drinking water, wastewater, river, aquaculture, process water...
  • Parameters to measure: pH, ORP, turbidity, dissolved oxygen, conductivity...
  • Installation and output: submersible / pipeline, RS485, 4-20mA, Modbus...
  • Quantity, target model, delivery country or project schedule
If you are not sure which sensor is suitable, describe your application and measured medium. Our team will help select the model.