PRODUCTS

Accessories/Components

video
product name

YEX-ACC-Clean-1 Online Self-Cleaning Holder for Water Quality Sensors

Brand: YexSensor

Model: YEX-ACC-Clean-1

Output: RS485 / Modbus parameter setting for cleaning interval and revolutions

Power: 12-24V DC

IP Rating: Waterproof wiring required for submerged or outdoor use

Range: Automatic brush cleaning for online water quality sensors

Description: YexSensor YEX-ACC-Clean-1 is an online self-cleaning holder for water quality sensors, designed to reduce fouling, support RS485/Modbus cleaning parameter setting and lower site maintenance workload.

Products Description

YexSensor YEX-ACC-Clean-1 Online Self-Cleaning Holder: Reliable Accessories for Water Quality Monitoring Systems

In long-term water quality monitoring projects, sensor fouling, microbial attachment and suspended solids can gradually affect measurement stability and increase maintenance frequency. YexSensor YEX-ACC-Clean-1 Online Self-Cleaning Holder integrates a motor-driven cleaning brush with a sensor mounting structure, helping system integrators keep sensor windows cleaner and reduce manual site visits in wastewater, surface water and industrial process water applications.

Core Technical Advantages: Easier Installation, Lower Maintenance and Stable Field Operation

Automatic Brush Cleaning

The built-in motor drive, position detection circuit and cleaning brush help remove contamination from the sensor surface and reduce biofouling during continuous online monitoring.

Multi-Sensor Installation Support

The holder can support up to four digital sensors at the same time, including dissolved oxygen, pH, ORP, conductivity and turbidity sensors, depending on project configuration.

Configurable RS485/Modbus Parameters

Cleaning interval and cleaning revolutions can be configured through the RS485 interface using Modbus communication, with default settings suitable for common monitoring sites.

YexSensor YEX-ACC-Clean-1 Online Self-Cleaning Holder Application Scenarios

YEX-ACC-Clean-1 is designed for water quality monitoring projects that require practical installation accessories, reduced maintenance workload and stable sensor operation.

Wastewater Treatment Plants

Reduces manual cleaning work for sensors exposed to sludge, suspended solids and biological growth.

Surface Water Monitoring Stations

Improves sensor stability in rivers, lakes and source-water monitoring points.

Industrial Process Water

Helps keep sensor measuring windows clean in circulating water or process water systems.

Aquaculture Monitoring

Supports long-term online monitoring where biofouling and algae attachment are common.

YexSensor YEX-ACC-Clean-1 Online Self-Cleaning Holder Technical Performance Parameters

Technical ItemParameter Details
Brand / ModelYexSensor / YEX-ACC-Clean-1
Product TypeOnline self-cleaning holder
Supported SensorsUp to four digital sensors depending on project configuration
Cleaning ModeMotor-driven brush cleaning
Default Cleaning Interval30 minutes
Default Cleaning Revolutions3 turns forward and backward
Operating Temperature-5 to 50 deg C
Power Supply12-24V DC
Power Consumption0.1W @ 12V
Cable Specification4-core shielded cable, 5 m, customizable
CommunicationRS485 / Modbus for cleaning parameter setting
Mounting Interface3/4 inch NPT thread

YexSensor YEX-ACC-Clean-1 Online Self-Cleaning Holder Installation and Electrical Integration Guidelines

Main Installation and Wiring Requirements

Brush Position

Install the sensor so the cleaning brush just contacts the measuring area. Too close may scratch the surface, while too far reduces cleaning effect.

Cable Definition

Red: 12-24V DC; Black: GND; Blue: RS485 A; White: RS485 B; bare wire: shield.

Waterproof Treatment

All wiring points must be waterproofed, especially when the cable is immersed in water or exposed outdoors.

Maintenance and Commissioning Guide

Routine Maintenance Tasks

Routine Check

Check brush rotation, cable condition and sensor surface cleanliness during regular maintenance.

Parameter Setting

The default Modbus data format is 9600, n, 8, 1. Cleaning interval and revolutions can be adjusted according to water quality conditions.

Commissioning Recommendations

Before formal operation, check mechanical installation, cable sealing, sample flow or cleaning action according to the product type. For integration projects, keep a record of sensor model, installation position, wiring definition, communication address and maintenance interval so that future site service can be performed efficiently.

Frequently Asked Questions (FAQ)

Q1: Is YEX-ACC-Clean-1 suitable for system integrators?

A1: Yes. It is designed as an accessory/component for water quality monitoring projects where reliable installation and easier maintenance are important.

Q2: Which sensors can be used with it?

A2: It can be used with YexSensor water quality sensor systems. Final compatibility should be confirmed according to sensor diameter, mounting thread, cable routing and project configuration.

Q3: Does it help reduce maintenance work?

A3: Yes. The product is intended to improve installation consistency and reduce common field problems such as fouling, unstable mounting, difficult inspection or repeated manual adjustment.

Q4: Can it be used in wastewater or surface water projects?

A4: Yes. It is suitable for water treatment, wastewater, surface water, process water and other monitoring projects when installed with proper protection and maintenance planning.

Q5: What should be checked before installation?

A5: Confirm sensor model, installation thread, cable definition, power supply if required, sample flow condition and whether the installation space allows cleaning and calibration.

Q6: Are waterproof measures required?

A6: Yes. For wet, outdoor or submerged applications, all terminals, cable joints and mechanical interfaces should be sealed to prevent water ingress and corrosion.

Q7: Can parameters be adjusted through RS485/Modbus?

A7: For self-cleaning models, cleaning interval and cleaning revolutions/speed can be configured through RS485/Modbus according to the manual. Passive flow cell components do not require communication.

Q8: What information is needed before ordering?

A8: Please provide sensor model, quantity, installation environment, water quality condition, mounting method, cable length and whether automatic cleaning or flow-through installation is required.

Send Inquiry(Tell us your requirements,Let's discuss more about your project,we can do more.)