Output: RS485 / Modbus parameter setting for cleaning interval and speed

Power: 12-24V DC

IP Rating: Waterproof and corrosion-resistant wiring required

Range: Multi-sensor automatic cleaning bracket

Description: YexSensor YEX-ACC-Clean-2 is an online self-cleaning bracket for multi-parameter water quality sensors, supporting automatic brush cleaning, RS485/Modbus parameter setting and long-term online monitoring.

Products Description

YexSensor YEX-ACC-Clean-2 Online Self-Cleaning Bracket: Reliable Accessories for Water Quality Monitoring Systems

For multi-parameter water quality monitoring stations, several sensors may operate continuously in water with suspended solids, biological growth or chemical fouling. YexSensor YEX-ACC-Clean-2 Online Self-Cleaning Bracket provides an integrated mounting and automatic cleaning solution for digital sensors, helping contractors improve data continuity and reduce routine manual cleaning work.

Core Technical Advantages: Easier Installation, Lower Maintenance and Stable Field Operation

Automatic Cleaning for Long-Term Monitoring

The built-in motor, position detection circuit and cleaning brush remove contamination from the sensor surface and help prevent microorganism attachment.

Supports Multiple Water Quality Sensors

The bracket supports optional installation of dissolved oxygen, conductivity, turbidity, pH, ORP and other digital sensors for multi-parameter online monitoring.

External Cleaning Expansion

According to field needs, customers can combine jet pipes, water spray pipes, ultrasonic cleaning heads or sodium hypochlorite antifouling devices with the bracket system.

YexSensor YEX-ACC-Clean-2 Online Self-Cleaning Bracket Application Scenarios

YEX-ACC-Clean-2 is designed for water quality monitoring projects that require practical installation accessories, reduced maintenance workload and stable sensor operation.

Integrated Monitoring Stations

Suitable for online stations requiring several water quality parameters in one installation structure.

Municipal Wastewater Projects

Reduces fouling-related maintenance for sensors in treatment process monitoring.

Seawater or Aquaculture Sites

Supports antifouling designs where biological attachment is a recurring issue.

Industrial Water Systems

Helps maintain sensor cleaning in recycled water, cooling water and process water applications.

YexSensor YEX-ACC-Clean-2 Online Self-Cleaning Bracket Technical Performance Parameters

Technical ItemParameter Details
Brand / ModelYexSensor / YEX-ACC-Clean-2
Product TypeOnline self-cleaning bracket
Supported SensorsUp to four digital sensors for five water quality parameters
Cleaning ModeMotor-driven brush cleaning
Default Cleaning Interval30 minutes
Default Cleaning Speed3 revolutions each way
Operating Temperature-5 to 50 deg C
Power Supply12-24V DC
Power Consumption0.1W @ 12V
Cable Specification4-core shielded cable, 5 m, customizable
Occupied Space85 mm x 85 mm x 20 mm
CommunicationRS485 / Modbus for cleaning parameter setting

YexSensor YEX-ACC-Clean-2 Online Self-Cleaning Bracket Installation and Electrical Integration Guidelines

Main Installation and Wiring Requirements

Sensor Contact Distance

The brush should just touch the sensor measuring area. Incorrect distance may reduce cleaning performance or damage the measurement surface.

Cable Definition

Red: 12-24V DC; Black: GND; Blue: RS485 A; White: RS485 B. Check wiring sequence carefully before powering on.

Corrosion Protection

Use waterproof and corrosion-resistant cable treatment for long-term immersion, seawater or outdoor exposure.

Maintenance and Commissioning Guide

Routine Maintenance Tasks

Routine Check

Inspect brush movement, motor response, cable sealing and sensor surface condition regularly.

Modbus Settings

Default Modbus format is 9600, n, 8, 1. Cleaning interval range is 6 to 6000 minutes, and cleaning speed range is 0 to 10.

Commissioning Recommendations

Before formal operation, check mechanical installation, cable sealing, sample flow or cleaning action according to the product type. For integration projects, keep a record of sensor model, installation position, wiring definition, communication address and maintenance interval so that future site service can be performed efficiently.

Frequently Asked Questions (FAQ)

Q1: Is YEX-ACC-Clean-2 suitable for system integrators?

A1: Yes. It is designed as an accessory/component for water quality monitoring projects where reliable installation and easier maintenance are important.

Q2: Which sensors can be used with it?

A2: It can be used with YexSensor water quality sensor systems. Final compatibility should be confirmed according to sensor diameter, mounting thread, cable routing and project configuration.

Q3: Does it help reduce maintenance work?

A3: Yes. The product is intended to improve installation consistency and reduce common field problems such as fouling, unstable mounting, difficult inspection or repeated manual adjustment.

Q4: Can it be used in wastewater or surface water projects?

A4: Yes. It is suitable for water treatment, wastewater, surface water, process water and other monitoring projects when installed with proper protection and maintenance planning.

Q5: What should be checked before installation?

A5: Confirm sensor model, installation thread, cable definition, power supply if required, sample flow condition and whether the installation space allows cleaning and calibration.

Q6: Are waterproof measures required?

A6: Yes. For wet, outdoor or submerged applications, all terminals, cable joints and mechanical interfaces should be sealed to prevent water ingress and corrosion.

Q7: Can parameters be adjusted through RS485/Modbus?

A7: For self-cleaning models, cleaning interval and cleaning revolutions/speed can be configured through RS485/Modbus according to the manual. Passive flow cell components do not require communication.

Q8: What information is needed before ordering?

A8: Please provide sensor model, quantity, installation environment, water quality condition, mounting method, cable length and whether automatic cleaning or flow-through installation is required.

Send Inquiry(Tell us your requirements,Let's discuss more about your project,we can do more.)