Products Description
YexSensor YEX-DCC-01 Bluetooth Wireless Transmission Module: Easier Field Data Collection for Water Quality Sensors
In water treatment plants, industrial wastewater sites and environmental monitoring projects, engineers often need to read sensor values before the full control cabinet or SCADA system is completed. YexSensor YEX-DCC-01 Bluetooth Wireless Transmission Module provides a practical short-distance data collection tool for RS485 water quality sensors, helping commissioning teams reduce temporary wiring, verify sensor status faster and improve field service efficiency.
Core Technical Advantages: Stable Data Collection, Standard Interfaces and Engineering Reliability
Wireless Data Reading for Field Commissioning
YEX-DCC-01 helps engineers access sensor data during installation, inspection and troubleshooting without repeatedly changing temporary wiring. It is especially useful when the control cabinet is not ready or when sensors are installed in locations that are difficult to reach.
RS485/Modbus-Oriented Integration
The module is designed around common water quality monitoring architectures. It works with RS485 sensor systems and supports project workflows where data must later be connected to PLCs, RTUs, gateways or cloud platforms.
Stable Field Service Design
The compact engineering housing, clear connection logic and sensor-oriented data reading process help reduce errors caused by loose wiring, address mismatch or unclear commissioning records.
YexSensor YEX-DCC-01 Bluetooth Wireless Transmission Module Application Scenarios
YEX-DCC-01 is designed for water quality monitoring projects that require stable data reading, clear field operation and easy system integration.
Water Treatment Plant Commissioning
Used during sensor installation and process testing before the main cabinet is fully online.
Industrial Wastewater Inspection
Supports mobile inspection of discharge points and temporary monitoring locations.
River and Source-Water Stations
Helps engineers read values from sensors installed in distributed outdoor monitoring points.
After-Sales Service
Useful for checking RS485 water quality sensors during maintenance visits.
YexSensor YEX-DCC-01 Bluetooth Wireless Transmission Module Technical Performance Parameters
| Technical Item | Parameter Details |
|---|---|
| Brand / Model | YexSensor / YEX-DCC-01 |
| Product Type | Bluetooth wireless transmission module |
| Main Function | Short-distance wireless sensor data reading |
| Communication Architecture | Designed for RS485/Modbus water quality sensor systems |
| Application Mode | Field commissioning, mobile inspection and temporary data collection |
| Power Supply | Configured according to the sensor system power supply |
| Installation / Use | Portable field service use |
| System Compatibility | Suitable for PLC, RTU, gateway and cloud platform integration projects |
YexSensor YEX-DCC-01 Bluetooth Wireless Transmission Module Installation and Electrical Integration Guidelines
Main Installation and Wiring Requirements
Connection Check
Confirm sensor power supply, RS485 A/B polarity, communication address and baud rate before use.
Field Use
Keep signal wiring away from high-voltage cables and inverter lines; use shielded twisted-pair cable for RS485 projects.
Protection Tip
For outdoor or humid locations, keep connectors and temporary wiring protected from water ingress.
Maintenance and Commissioning Guide
Routine Maintenance Tasks
Routine Inspection
Check connector tightness, sensor response and communication stability before recording field data.
Commissioning Record
Record sensor model, address, baud rate and measured value after successful reading to reduce later integration errors.
Commissioning Recommendations
Before connecting the device to an upper-level automation system, complete single-device testing first. Confirm power supply, signal polarity, communication address, baud rate, sensor value stability and platform mapping. For project delivery, keep a written commissioning record so that future operation and maintenance teams can quickly trace settings and wiring conditions.
Frequently Asked Questions (FAQ)
Q1: Is YEX-DCC-01 suitable for system integrators?
A1: Yes. It is designed for engineering projects where water quality sensors must be connected, displayed, commissioned and integrated into automation or remote monitoring systems.
Q2: Does it support RS485/Modbus architecture?
A2: Yes. YexSensor data collection and control products are developed around RS485/Modbus water quality monitoring workflows, although the exact connection should be confirmed according to the sensor model and project configuration.
Q3: How does it help improve field stability?
A3: It supports standardized wiring, clear parameter management and stable communication logic, reducing common site problems such as polarity errors, address conflicts, poor grounding and unstable signal routing.
Q4: Can it connect to PLC, DCS or SCADA systems?
A4: Yes. Depending on the project configuration, it can work with PLCs, DCS systems, RTUs, edge gateways, SCADA software and cloud platforms through standard digital or analog interfaces.
Q5: What should be checked first if communication fails?
A5: Check power supply, RS485 A/B polarity, baud rate, device address, shielding and whether multiple devices share the same address on the bus.
Q6: Can it be used in outdoor water quality monitoring projects?
A6: Yes, but outdoor or humid applications should use a proper control cabinet, waterproof enclosure or station structure to protect terminals, cables and power connections.
Q7: Which water quality parameters can be integrated?
A7: It can be used with YexSensor water quality sensor systems for common parameters such as pH, ORP, conductivity, dissolved oxygen, turbidity and other project-specific measurements.
Q8: What information is needed before selecting a model?
A8: Please provide sensor model, quantity, output signal type, installation environment, power supply condition, required display/control functions and the target PLC, gateway or platform interface.