PRODUCTS

Level Sensors & Meters

YEX-HY-RFMS-01 Radar Flow Meter Sensor
video
YEX-HY-RFMS-01 Radar Flow Meter Sensor

YEX-HY-RFMS-01 Radar Flow Meter Sensor

Thương hiệu: YexSensor

Mẫu: YEX-HY-RFMS-01

Đầu ra: RS485 Modbus RTU

Nguồn cấp: DC 10-30V

Cấp bảo vệ IP: Non-contact radar

Dải đo: 0.1-20 m/s, 0.1-65 m

Mô tả: YEX-HY-RFMS-01 Radar Flow Meter Sensor from YexSensor supports stable hydrology monitoring with RS485 Modbus RTU, reliable field installation and easy system integration.

Mô tả sản phẩm

YEX-HY-RFMS-01 Radar Flow Meter Sensor

Non-contact velocity and level monitoring for open-channel flow measurement.

YexSensor YEX-HY-RFMS-01 combines radar velocity measurement and radar water level measurement for open-channel flow applications. It helps integrators build a more maintainable monitoring system where submerged sensors are difficult to install or maintain.

Core Technical Advantages

  • 24.00 GHz radar velocity sensing supports stable surface velocity measurement without direct water contact.

  • 76-81 GHz radar level measurement provides high-resolution distance feedback for flow calculation.

  • Non-contact installation reduces risks caused by silt, debris, corrosion and sensor fouling.

  • RS485 Modbus RTU output enables direct connection to PLC, RTU and remote monitoring platforms.

Application Scenarios

  • Open-channel flow monitoring

  • River and flood discharge monitoring

  • Urban drainage network monitoring

  • Irrigation canal flow measurement

  • Hydrological station upgrades

Technical Performance Parameters

Brand / ModelYexSensor / YEX-HY-RFMS-01
Power SupplyDC 10-30V
Maximum Power1.3W
Velocity Radar Frequency24.00GHz
Velocity Range0.1-20 m/s
Velocity Accuracy+/-2%
Velocity Resolution0.01 m/s
Level Radar Frequency76GHz-81GHz
Water Level Range0.1-65 m
Distance Accuracy+/-1 mm
Distance Resolution1 mm
Operating Height0-20 m
OutputRS485 Modbus RTU
Operating Temperature-40 deg C to +80 deg C
Humidity0-95%RH, non-condensing

Installation and Wiring Guide

Install the sensor above the channel and align the sensing direction with the water flow. The preferred position is near the channel center or a representative flow section with a stable water surface.

Wiring note: Use DC 10-30V power and RS485 A/B communication wiring. Keep power and signal cables away from high-voltage or high-current lines.

Maintenance and Commissioning Guide

Inspect the mounting bracket, cable entry and radar window periodically. Verify flow section parameters when the channel profile changes.

Frequently Asked Questions

Q1: Does the sensor need to be placed in water?

A1: No. The radar flow meter is installed above the channel, reducing fouling and maintenance.

Q2: What data can it output?

A2: It can provide velocity and water level data for flow calculation and remote monitoring.

Q3: Is it suitable for dirty water?

A3: Yes. The non-contact structure is well suited to drainage, rivers and channels with silt or debris.

Q4: Can it communicate with SCADA?

A4: Yes. RS485 Modbus RTU supports PLC, RTU and SCADA integration.

Q5: What affects velocity accuracy?

A5: Installation angle, water surface condition and selected flow section are key factors.

Q6: Can it be used outdoors?

A6: Yes. It is designed for hydrology and outdoor monitoring environments.

Q7: Does it measure full-pipe flow?

A7: It is mainly intended for open-channel or non-contact surface flow applications.

Q8: How should it be commissioned?

A8: Confirm mounting angle, channel parameters, communication address and Modbus register reading.

Summary

YEX-HY-RFMS-01 is a strong fit for non-contact open-channel flow projects where stable measurement, lower maintenance and Modbus-based integration are priorities.

Yêu cầu đề xuất cảm biến