Description du produit
YEX-HY-RFMS-01 Radar Flow Meter Sensor
Non-contact velocity and level monitoring for open-channel flow measurement.
YexSensor YEX-HY-RFMS-01 combines radar velocity measurement and radar water level measurement for open-channel flow applications. It helps integrators build a more maintainable monitoring system where submerged sensors are difficult to install or maintain.
Core Technical Advantages
24.00 GHz radar velocity sensing supports stable surface velocity measurement without direct water contact.
76-81 GHz radar level measurement provides high-resolution distance feedback for flow calculation.
Non-contact installation reduces risks caused by silt, debris, corrosion and sensor fouling.
RS485 Modbus RTU output enables direct connection to PLC, RTU and remote monitoring platforms.
Application Scenarios
Open-channel flow monitoring
River and flood discharge monitoring
Urban drainage network monitoring
Irrigation canal flow measurement
Hydrological station upgrades
Technical Performance Parameters
| Brand / Model | YexSensor / YEX-HY-RFMS-01 |
| Power Supply | DC 10-30V |
| Maximum Power | 1.3W |
| Velocity Radar Frequency | 24.00GHz |
| Velocity Range | 0.1-20 m/s |
| Velocity Accuracy | +/-2% |
| Velocity Resolution | 0.01 m/s |
| Level Radar Frequency | 76GHz-81GHz |
| Water Level Range | 0.1-65 m |
| Distance Accuracy | +/-1 mm |
| Distance Resolution | 1 mm |
| Operating Height | 0-20 m |
| Output | RS485 Modbus RTU |
| Operating Temperature | -40 deg C to +80 deg C |
| Humidity | 0-95%RH, non-condensing |
Installation and Wiring Guide
Install the sensor above the channel and align the sensing direction with the water flow. The preferred position is near the channel center or a representative flow section with a stable water surface.
Wiring note: Use DC 10-30V power and RS485 A/B communication wiring. Keep power and signal cables away from high-voltage or high-current lines.
Maintenance and Commissioning Guide
Inspect the mounting bracket, cable entry and radar window periodically. Verify flow section parameters when the channel profile changes.
Frequently Asked Questions
Q1: Does the sensor need to be placed in water?
A1: No. The radar flow meter is installed above the channel, reducing fouling and maintenance.
Q2: What data can it output?
A2: It can provide velocity and water level data for flow calculation and remote monitoring.
Q3: Is it suitable for dirty water?
A3: Yes. The non-contact structure is well suited to drainage, rivers and channels with silt or debris.
Q4: Can it communicate with SCADA?
A4: Yes. RS485 Modbus RTU supports PLC, RTU and SCADA integration.
Q5: What affects velocity accuracy?
A5: Installation angle, water surface condition and selected flow section are key factors.
Q6: Can it be used outdoors?
A6: Yes. It is designed for hydrology and outdoor monitoring environments.
Q7: Does it measure full-pipe flow?
A7: It is mainly intended for open-channel or non-contact surface flow applications.
Q8: How should it be commissioned?
A8: Confirm mounting angle, channel parameters, communication address and Modbus register reading.
Summary
YEX-HY-RFMS-01 is a strong fit for non-contact open-channel flow projects where stable measurement, lower maintenance and Modbus-based integration are priorities.