Products Description
online conductivity sensor, conductivity sensor, RS485 conductivity transmitter, industrial conductivity meter, 4-20mA conductivity probe, water quality conductivity sensor, conductivity meter
YEX-S2-EC-S High Precision Online Conductivity Sensor
High-Precision Stable Online Conductivity Monitoring Solution for Industrial Water Treatment
In industrial water treatment, seawater aquaculture, circulating cooling water systems and wastewater discharge monitoring, traditional conductivity sensors often face problems such as large temperature drift, weak anti-interference ability, poor long-term stability and integration difficulties. The Yexsensor YEX-S2-EC-S online conductivity sensor adopts precision measurement technology and industrial-grade design to provide high-precision, highly stable and easy-to-integrate online conductivity monitoring solutions for complex water quality environments.
Core Selling Points
High-precision measurement and Pt1000 automatic temperature compensation, ensuring reliable data across the full 0~5000μS/cm range
RS485 Modbus/RTU + 4-20mA dual output mode, easy integration with various industrial control systems
IP68 protection rating and 316L stainless steel wetted parts, suitable for long-term submersion and corrosive media environments
YEX-S2-EC-S Online Conductivity Sensor Product Overview
The Yexsensor YEX-S2-EC-S online conductivity sensor is developed for industrial on-site online monitoring and can accurately measure water conductivity (0~5000μS/cm) in real time. The product features a built-in Pt1000 temperature sensor for automatic temperature compensation, effectively reducing the impact of temperature changes on measurement results. It supports dual signal outputs of RS485 (Modbus/RTU) and 4-20mA, compatible with PLC, DCS, industrial control computers, paperless recorders and touch screens, helping users build stable and reliable water quality monitoring and automation control platforms.
YEX-S2-EC-S Online Conductivity Sensor Key Advantages
1. High Precision and Temperature Compensation Optimization
Measurement accuracy reaches ±1.5%F.S. (conductivity) and ±0.3℃ (temperature), with a resolution of 1μS/cm. It uses two-point calibration combined with Pt1000 automatic temperature compensation algorithm, maintaining excellent stability within the 0~60℃ operating range, significantly reducing measurement errors caused by temperature fluctuations and meeting the stringent requirements of industrial process control.
2. Strong Anti-Interference and Flexible Integration Capability
Adopts RS485 digital communication (Modbus/RTU protocol) and 4-20mA analog output. The dual output design greatly improves system compatibility. The 5-core shielded twisted pair effectively resists electromagnetic interference in industrial sites, supports long-distance transmission and multi-device networking, and facilitates seamless integration into existing control systems, reducing integration costs and wiring complexity.
3. Industrial-Grade Protection and Corrosion-Resistant Design
IP68 protection rating allows long-term submersion. Wetted materials combine ABS, POM and 316L stainless steel with excellent corrosion resistance. Equipped with M16-5 pin waterproof connector and 5-meter anti-corrosion shielded cable (customizable). The 3/4 NPT thread installation method is suitable for pipe, tank and immersion installation, making installation and maintenance convenient.
4. Low Power Consumption and Standardized Maintenance
Power consumption is only 0.2W@12V, suitable for continuous online operation. It undergoes 72-hour aging and stability testing before leaving the factory. Maintenance is simple: regularly clean the electrode surface with a soft brush and rinse with distilled water, then maintain performance with two-point calibration, significantly reducing user operation and maintenance costs.
YEX-S2-EC-S Online Conductivity Sensor Technical Specifications
| Parameter | Specification |
|---|---|
| Model | YEX-S2-EC-S |
| Measurement Range | 0~5000μS/cm |
| Resolution | 1μS/cm, 0.1℃ |
| Accuracy | ±1.5%F.S., ±0.3℃ |
| Operating Temperature | 0~60℃ |
| Operating Pressure | <0.6 MPa |
| Power Supply | 12~24VDC |
| Signal Output | RS-485 (Modbus/RTU), 4-20mA |
| Temperature Compensation | Automatic Temperature Compensation (Pt1000) |
| Calibration Method | Two-point calibration |
| Wetted Materials | ABS, POM, 316L Stainless Steel |
| Installation Method | Submersible Installation, 3/4 NPT Thread |
| Cable Length | 5 meters (customizable) |
| Power Consumption | 0.2W@12V |
| Protection Rating | IP68 |
| Connector Type | M16-5 Pin Waterproof Connector |
YEX-S2-EC-S Online Conductivity Sensor Application Scenarios
Industrial Circulating Cooling Water Systems: Real-time monitoring of cooling water conductivity to control concentration multiples and prevent equipment scaling and corrosion.
Wastewater Treatment and Discharge Monitoring: Online detection of inlet and outlet conductivity in wastewater treatment plants to ensure treatment effectiveness and discharge compliance.
Seawater Aquaculture and Aquatic Industry: Accurately grasp conductivity data related to salinity in aquaculture water bodies to optimize water quality management.
Boiler Feed Water and Pure Water Preparation: Monitor water purity changes in processes such as reverse osmosis and ion exchange.
Food & Beverage and Pharmaceutical Production: Monitor conductivity of process water and solutions to ensure process consistency and product quality.
FAQ
Q1: What output signals does the YEX-S2-EC-S support?
A1: It supports both RS-485 (Modbus/RTU protocol) and 4-20mA analog output, meeting the integration needs of different control systems.
Q2: Does the sensor have automatic temperature compensation?
A2: Yes. It has a built-in Pt1000 precision temperature sensor that realizes full-range automatic temperature compensation and effectively eliminates temperature influence.
Q3: What are the requirements for installation position?
A3: During installation and testing, the sensor should be at least 2cm away from the bottom and side walls of the container to avoid boundary effects interfering with measurement accuracy.
Q4: How to perform calibration?
A4: Use two-point calibration. First clean with distilled water and perform zero-point calibration in air, then place in standard solution for slope calibration.
Q5: Are the cable and connector suitable for long-term immersion?
A5: The cable is anti-corrosion shielded wire with M16-5 pin waterproof connector. All interfaces are waterproofed and support long-term immersion.
Q6: How is the corrosion resistance of the wetted materials?
A6: The combination of ABS, POM and 316L stainless steel is suitable for most industrial water bodies and mildly corrosive media environments.
Q7: How to determine the maintenance cycle?
A7: It is recommended to regularly clean the electrode and calibrate according to the actual medium cleanliness. The specific cycle is determined by the user based on site conditions.
Q8: Does the product provide customization services?
A8: Yes. Cable length customization and other reasonable technical parameter adjustments are supported. Please contact the technical team to discuss specific requirements.
Summary
With high-precision measurement, dual signal output, strong anti-interference capability and reliable protection design, the Yexsensor YEX-S2-EC-S online conductivity sensor has become a trustworthy online monitoring device in the industrial water treatment field. It helps engineering technicians achieve precise control of water quality parameters and improves system automation level and operational stability.
Need product selection guidance, on-site installation solutions or customized services? Feel free to contact the Yexsensor professional technical support team at any time. We will provide you with comprehensive engineering solutions.